Operating environment:                    Temperature -+5 ℃ to  +35 ℃, relative humidity 70 % or less without codensation
Storage environment:                         Temperature -0 ℃ to + 40 ℃, relative humidity 70 % or less without codensation
Division ratio:                                           1:100 
Input resistance:                                     Approx. 1×1010 Ω
Maximum measurement voltage: 2. 5 kVDC (continuous)
Measurment accuracy:                       ±3 % of rdg ±5 ppm/V
Output connector:                                 Triaxial connector
Dimensions:                                              Approx. 29 (maximum diameter)  ×174(length)mm, 1000 mm (cable length)
Mass:                                                             200 g or less
Connection of 12602 and 8252


Operating environment:                       Temperature -+5 ℃ to  +35 ℃, relative humidity 70 % or less without codensation
Storage environment:                            Temperature -0 ℃ to + 40 ℃, relative humidity 70 % or less without codensation
Capacitance:                                                100 pF or less 
Insulation resistance:                             1014Ω
Signal line reisstance:                             0.2 Ω or less 
Maximum allowable input voltage: 1100 VDC (for 1 minute, not exceeding the maximum allowable input voltage of the electrometer)
Maximum allowable input current: 2 ADC
Output connector:                                    Triaxial connector
                                                                            *To connect to the 5450, the CC015003 is required.
Dimensions:                                                  Approx. 29 (maximum diameter) ×174 (length) mm, 1000 mm (cable length)
Mass:                                                                200 g or less
Connection of 12603 and 5350


The 12604 is connected to the 5450/5451 to measure the insulation resistance of chip capacitors. With the tweezers-like shape, small chip components can be measured easily and efficiently. In particular the A08076 (optional) shield measurement plate is Teflon-coated, allowing measurement with little inductive noise.
Operating environment:                       Temperature -+5 ℃ to  +35 ℃, relative humidity 70 % or less without codensation
Storage environment:                            Temperature -0 ℃ to + 40 ℃, relative humidity 70 % or less without codensation
Connectors:                                                  Input triaxial connector, voltage application, banana-tip
Dielectric strength/insulation resistance: 
| Dielectric strength | insulation resistance (Ω) | |
| INPUT signal line - V SOURCE | 1.1 kV | 1014 or more | 
| INPUT signal line - chassis | 1.1 kV | 1014or more | 
| V SOURCE - chassis | 1.1 kV | 109or more | 
Allowable applied voltage:                  100 VDC
Applicable sample:                                  Chip components with an electrode distance of 1.0 to 8.0 mm
Dimensions:                                                 Approx. 28 (W) × 13 (H) × 140 (D) mm, 1 m (cable length)
Mass:                                                                200 g or less